These early 1960’s stone built properties could not be insulated using standard cavity wall insulation products due to having variable width cavities and a random stone outer leaf.
These early 1960’s stone built properties could not be insulated using standard cavity wall insulation products due to having variable width cavities and a random stone outer leaf.
After a comprehensive borescope survey, Technitherm® insulation and stabilisation foam was injected into the cavity. The injected liquid was able to flow around the cavity with the resulting foam produced expanding and filling all the void.