The properties had previously been installed with mineral wool which was not suitable due to the high exposure zone and the soft and porous nature of the bricks, both of which have led to premature wall tie failures and the mineral wool insulation to become wet, causing damp and colder homes.

The Project

The properties had previously been installed with mineral wool which was not suitable due to the high exposure zone and the soft and porous nature of the bricks, both of which have led to premature wall tie failures and the mineral wool insulation to become wet, causing damp and colder homes.

The Solution

Firstly, the mineral wool was extracted by our approved contractor British Insulation Services. Once clear, Technitherm® Cavity Wall System was then injected by British Insulation Services into the 60-70mm cavity wall through a series of 12mm holes drilled through the mortar joints of the external brickwork. Technitherm® KIWA Certificate No. BAW-18-037-S-A-UK and BAW-18-038-S-A-UK, firstly provides structural stabilisation, this is done by bonding to the inner and outer leaves which negates the previously failed wall ties, and additionally provides up to twice the thermal values of the wool that was previously installed.

The Outcome:

The properties are now better insulated giving an average uvalue of 0.33, and due to the stabilisation of Technitherm® the walls are also now stronger and secure, without the need to replace the failing wall ties, not only will this improve the properties energy efficiency and EPC rating, but also prevent further deterioration of the walls structure over the lifetime of the properties.

Client:
Gateshead Council
Location:
Products:
Find An Installer ->