The properties had previously been installed with mineral wool which was not suitable due to the high exposure coastal zone, this mistake has led to premature wall tie failures and the mineral wool insulation to become wet, causing damp and colder homes.
The properties had previously been installed with mineral wool which was not suitable due to the high exposure coastal zone, this mistake has led to premature wall tie failures and the mineral wool insulation to become wet, causing damp and colder homes.
Firstly, the mineral wool was extracted by our approved contractor Prize Insulation Ltd Once clear, Technitherm® Cavity Wall System was then injected by Prize Insulation into the 70mm cavity wall through a series of 12mm holes drilled through the mortar joints of the external render and brickwork. Technitherm® KIWA Certificate No. BAW-18-037-S-A-UK and BAW-18-038-S-A-UK, firstly provides structural stabilisation, this is done by bonding to the inner and outer leaves which negates the previously failed wall ties, and additionally provides up to twice the thermal values of the wool that was previously installed.